Drawings
EASTERN DOOR SERVICE
Revised December 7, 2002
AUTOMATIC WINDOWS
SERIES 8000
PART I - GENERAL
1.01 DESCRIPTION
This section covers the furnishing and installation of automatic windows and activating
devices all as required for installation as shown and specified. The General Contractor
shall coordinate the work of all trades including the automatic door supplier, hardware
supplier, carpenter, mason, and electrician as so specified.
1.02 RELATED WORK COVERED BY OTHER APPLICABLE SECTIONS OF
SPECIFICATION SHALL INCLUDE:
A. Preparation of Opening
B. Electrical Supply and Connections (120 VAC Dedicated Circuit)
C. Caulking
1.03 QUALITY ASSURANCE
A. UL 325
Provide powered window operators complying with UL 325, Electrical Door, Drapery,
Gate, Louver, and Window Operators and Systems.
B. MANUFACTURER'S QUALIFICATIONS
Provide units produced by a firm with not less than 5 years successful experience in the
fabrication of automatic doors of the type required for this project.
C. INSTALLER'S QUALIFICATIONS
Engage an installer who has an AAADM certified inspector on staff and is an
authorized representative of the automatic window manufacturer for both the installation
and maintenance of the type of units required for this project.
1.04 SUBMITTALS
A. PRODUCT DATA
Submit manufacturer's product data and standard details for automatic windows,
including fabrication, finishing hardware, operators, accessories, and other components of
the work. Include rough-in diagrams, wiring diagrams, parts lists, and maintenance
instructions, as well as certified test data (where required).
B. TEMPLATES AND DIAGRAMS
Furnish templates, diagrams, and other data to fabricators and installers of
related work, as needed for coordination of automatic entrance installation.
C. SHOP DRAWINGS
Submit shop drawings for the fabrication and installation of automatic windows
and associated components of the work. Indicate anchors, joint system, expansion
provisions, hardware, and other components not included in manufacturer's standard data.
Include glazing details (where required).
1.05 WARRANTY
Units to be warranted against defect in material and workmanship for a period of one year
from the date of installation.
PART II - PRODUCT
2.01 MANUFACTURER
Furnish and install Series 8000 automatic window package and related equipment as
specified herein. The equipment shall be manufactured by Horton Automatics and as
supplied by Eastern Door Service, Inc. (800) 390-5521 www.EDSDoors.com
. The package shall consist of series 8000 window, operator and actuating device.
All equipment shall be listed by Underwriters Laboratories, Inc.
2.02 EQUIPMENT
A. MODEL
Furnish and install (note to specifier: please select model type below)
(a) Series 8100 single sliding, flush mounted
(b) Series 8100TS biparting, flush mounted
(c) Series 8200TS biparting, projected mounted
(d) Series 8300 single sliding, projected mounted, security interlocked
automatic window complete with operator and glazing.
B. WINDOW PACKAGE
Window package shall include operator, header, track, jambs, sliding window,
sill, sidelight, and pushbutton switch. Exposed aluminum surfaces shall be given a
satin etch and a clear anodized or dark bronze anodized hardcoat finish. (Also available
in black hardcoat finish if specified). All structural aluminum sections shall be
6063T-5 alloy not less than .125 inch thickness with safety radius corners on all vertical
rails. Continuous extruded header section shall conceal the high quality, ball bearing
wheels on nylon-covered support track. Concealed guides shall stabilize bottom of window.
Anti-derailing means shall be continuous extrusion full length of window travel. Track
must be replaceable without having to remove the operator. An adjustable astragal with
double mohair weatherstrip shall be provided on all strike rails. Joining vertical panel
rails shall have complementing mohair weatherstripping, while horizontal rails shall be
weatherstripped with mohair type fabric. Window panel construction shall be by means of
tongue-and-groove key fitted gussets that have two tempered bolts in each corner section
to assure against racking failure.
C. OPERATOR
Horton series 8000 gearless electromechanical linear drive train shall be header
mounted and concealed with a securely attached, removable cover. The opening speed,
closing speed, back check and latch check shall be fully and independently adjustable.
Braking or checking shall be an integral function of the operator for deceleration of the
moving panel. The operator's closing speed shall be field adjustable to not exceed one
foot per second closing speed. This shall be accomplished by utilizing the operator's
solid state master control which will include adjustments for aforementioned functions, as
well as time-delay. In case of electrical power failure, operator shall revert to
free manual operation of the window. A power ON and OFF switch shall be located on the
inside of the header and shall serve a second function as "hold open" for
window. A clutch shall be provided to regulate the closing force to a maximum of 30 lbs.
as is required by ANSI. The operator shall include an electronic sensing device that will
reverse the window from closing when a maximum force of 15 lbs. is exerted to prevent the
window from closing. The reverser shall be field adjustable to meet conditions.
2.03 CONTROL SWITCHES
Each sliding window unit shall include a WinScan active infra-red presence sensor
mounted above the window opening at the interior of the building. When presence is
detected at the window opening it shall open automatically. The presence sensor
pattern shall be adjustable to avoid unintentional actuation by cross traffic.
2.04 REQUIREMENTS FOR ELECTRICAL WORK BY OTHERS
The Electrical Contractor shall furnish and install all wiring to operator.
Provide 120 VAC, 60 cycle, 1 phase, 15 amp service to each operator (header) on a separate
circuit breaker routed into header. Remote switches (if specified) shall be provided with
control wire and electrical boxes from switches to operators. Remote switches provided
under this section shall be installed by the electrical contractor.
NOTE: Maximum current draw is 5 amps per operator protected by internal circuit breaker in
operator.
PART III - EXECUTION
3.01 INSPECTION
Installer must examine the areas and conditions under which automatic windows are to be
installed and notify the Contractor in writing of conditions detrimental to the proper and
timely completion of work. Do not proceed with the work until all unsatisfactory
conditions have been corrected in a manner acceptable to the installer and in accordance
with approved shop drawings.
3.02 INSTALLATION
Comply with specifications and recommendations. Set track and operator plumb, level and
true to line, without warp or rack of windows. Anchor securely in place. Isolate aluminum
and other corrodible materials from sources of electrolytic action at points of contact.
Install complete window operator system in accordance with manufacturer's instructions,
including drive mechanism, controls, and control switches.
3.03 ADJUST AND CLEAN
Adjust operator and controls for optimum condition and safety. Lubricate operating
equipment. Clean surfaces promptly after installation, exercising care to avoid damage of
the protective coating (if any). Advise contractor of protective treatment and other
precautions required through the remainder of the construction period, to ensure that
windows will be without damage or deterioration (other than normal weathering) at the time
of acceptance.
END OF SECTION
|