Drawings EASTERN DOOR
SERVICE
Revised July 27, 2002
LOW ENERGY
AUTOMATIC SWINGING DOOR OPERATOR
SERIES 7000 ELECTRIC OPERATOR
PART I - GENERAL
1.01 DESCRIPTION
This section includes furnishing of all labor, material and
equipment to perform all operations in connection with the automatic swing door operators,
specified herein and as shown on drawings. The General Contractor shall coordinate the
work of all trades including the automatic door supplier, door and frame supplier,
hardware supplier, carpenter, mason, and electrician as so specified.
1.02 RELATED WORK COVERED BY OTHER APPLICABLE SECTIONS OF
SPECIFICATION SHALL INCLUDE:
A. Preparation of Opening
B. Floor Preparation
C. Electrical Supply and Connections (120 VAC Dedicated Circuit)
D. Glass and glazing
E. Caulking
1.03 QUALITY ASSURANCE
A. ANSI A156.19 STANDARD
Provide automatic entrance doors complying with applicable requirements of Power Operated
Pedestrian Door Standard where applicable to door type.
B. UL 325
Provide powered door operators complying with UL 325, Electrical Door, Drapery,
Gate, Louver, and Window Operators and Systems.
C. MANUFACTURER'S QUALIFICATIONS
Provide units produced by a firm with not less than 5 years successful experience in the
fabrication of automatic doors of the type required for this project.
D. INSTALLER'S QUALIFICATIONS
Engage an installer who has an AAADM certified inspector on staff and is an
authorized representative of the automatic door manufacturer for both the installation and
maintenance of the type of units required for this project.
1.04 SUBMITTALS
A. PRODUCT DATA
Submit manufacturer's product data and standard details for automatic doors,
including fabrication, finishing hardware, operators, accessories, and other components of
the work. Include rough-in diagrams, wiring diagrams, parts lists, and maintenance
instructions, as well as certified test data (where required).
B. TEMPLATES AND DIAGRAMS
Furnish templates, diagrams, and other data to fabricators and installers of
related work, as needed for coordination of automatic entrance installation.
C. SHOP DRAWINGS
Submit shop drawings for the fabrication and installation of automatic entrance
doors and associated components of the work. Indicate anchors, joint system, expansion
provisions, hardware, and other components not included in manufacturer's standard data.
Include glazing details (where required).
1.05 WARRANTY
Units to be warranted against defect in material and workmanship for a period of one year
from the date of installation.
PART II - PRODUCT
2.01 MANUFACTURER
Series 7000 EasyAccess automatic swinging door operator(s) shall be of type(s) and
size(s) as indicated on plans, as manufactured by Horton Automatics, a division of the
Overhead Door Corporation and as supplied by Eastern Door Service, Inc.,
Florence,
NJ (800) 390-5521 http://www.EDSdoors.com.
2.02 EQUIPMENT
A. OPERATOR
The Electric Operating Mechanism shall be Series 7000. The Series 7000
EasyAccess operator shall be a low-energy, self-contained, electromechanical design.
The operator shall be powered open with a DC motor working through six reduction gears.
Closing shall be by spring force. The motor is to be off when the door is in the closing
mode. The door can be manually operated with power on or off without damage to the
operator. The control shall be furnished with a selection switch that provides for two
methods of actuating the automatic door. The selection switch enables the owner to select
the desired operation and adapt to changing conditions.
MANUAL/AUTOMATIC
Manual operation when pushed open, automatic operation when actuated by pushbutton switch.
AUTOMATIC
Automatic operation by either pushing the door manually to activate Push-N-Go or by
pushbutton switch. The Push-N-Go time delay shall be 30 percent less than pushbutton time
delay.
The operator shall include the following variable adjustments to
enable it to comply with Standard ANSI A156.19.
Opening speed 4 to 6 seconds
Closing speed 4 to 6 seconds
Time delay before closing 2 to 30 seconds (ANSI requirement is 5
second minimum time delay)
Opening and closing force, measured 2" (50.8 mm) out from the
lock stile of the door, not to exceed 15 pounds (67 N) of force to stop the door when
operating in either direction.
The operator shall include ``Time Out" feature. This feature
will turn off the opening force when the door is stopped for one second. The door then
begins to close. The operator immediately resets and will accept another opening signal.
The operator shall be mounted and concealed in an extruded aluminum cover not less than
.125 (3 mm) thickness in clear anodize (option dark bronze anodize). Cover shall be
4" x 6" (102 mm x 152 mm), running full width of door or a minimum 23" (584
mm) in length.
UNDERWRITERS LABORATORY LISTED
OPTION:
Emergency Breakout. In swinging doors shall be equipped with an
emergency breakout. When door is in emergency breakout position, power shall be removed
from the operator.
B. DOOR AND FRAME CONSTRUCTION (Series 7500 only)
OPTION: (Delete door and frame section if operator only is
furnished and state which section covers the door.)
Door and Frame shall be of heavy duty construction suitable for continuous automatic door
service. All structural members shall be of extruded tubular aluminum thickness of .125
inch (3.175 mm). Alloy shall be 6063-T5. Frame members shall be 1-3/4" x 4" (
44.45 mm x 101.6 mm) dimensions. Swing panel shall be assembled by means of
tongue-and-groove, key-fitted gussets that are bolted to prevent racking failure. Lock and
pivot rails shall have adjustable dual weatherstripping. Vinyl finger guards shall be
provided. Snap-in glazing beads with vinyl gasket shall be provided. The following
hardware shall be provided: (1) Maximum security lock, (2) Push bars, (3) Pivots, (4)
Finger guards, (5) Threshold.
All exposed surfaces shall be:
OPTIONS:
(1) Standard Finish: Caustic etch and anodic oxide treatment to
conform to aluminum association standards AA-M12C22A31 (204-R1).
(2) Stock Finish: An integral color hard coat finish dark bronze.
(3) Special Finish: An integral color hard coat finish (specify
color).
OPTION: The operator shall be (select operator type)
Series 7100
mounted to the surface of the existing door frame or wall and be concealed in a
6"x6" (152.4 mm x 152.4 mm) aluminum cover. Connecting hardware shall be a
double arm arrangement that can either push the door or pull the door open to suit the job
condition. When the operator mounting is on the pull side and an adjacent wall is within
4" (101.6 mm) of the door frame, specify a parallel arm.
Series 7800 or Series 7500 (complete package including door)
The operator is mounted directly over the door and is concealed in a 4½"x6"
(1371.6 mm x 152.4 mm) or 6"x6" (152.4 mm x 152.4 mm) aluminum cover that serves
as the door frame header. The cover shall be self-supporting to transom glass above. The
operator output shaft shall connect to an arm that transmits power to the door via a slide
block connected to the arm. The arm works in a track that is mounted in the top web of the
door. The door pivot is independent of the operator and the bottom door pivot is included.
OPTION: Direct drive available
OPTION: In swinging doors shall be equipped with an emergency
breakout. When door is in emergency breakout position, power shall be removed from the
operator.
C. FINISH
OPTIONS: All exposed surfaces shall be (Select desired finish)
1) 204-R1 clear anodized aluminum.
2) 313-R1 dark bronze anodized aluminum.
3) Manufacturer's standard two coat Duranar finish. Color to be
selected by architect from manufacturer's standard color chart.
4) Manufacturer's standard three coat Duranar XL finish. Color to be
selected by architect from manufacturer's standard XL color chart.
5) Manufacturer's standard exotic Duranar finish. Color to be
selected by architect from manufacturer's standard exotic color chart.
6) Special color and finish as indicated (optional)
2.03 CONTROL SWITCHES
Provide a Sedco model 59H 4½" x 4½" push plate switch engraved with the
international handicap insignia and "Press to Operate Door", - on each
side of the opening at the location shown on the drawing.
Option: Model 99H is a 6" round, push plate switch -
engraved with international handicap insignia and marked "Press to Open".
Option: BEA model SuperScan LE hold open presence sensor.
2.04 REQUIREMENTS FOR ELECTRICAL WORK BY OTHERS
The Electrical Contractor shall furnish and install all wiring to operator. Provide
120 VAC, 60 cycle, 1 phase, 15 amp service to each operator (header) on a separate circuit
breaker routed into header. Remote switches (if specified) shall be provided with control
wire and electrical boxes from switches to operators. Remote switches provided under this
section shall be installed by the electrical contractor.
NOTE: Maximum current draw is 5 amps per operator protected by
internal circuit breaker in operator.
PART III - EXECUTION
3.01 INSPECTION
Installer must examine the areas and conditions under which automatic doors are to be
installed and notify the Contractor in writing of conditions detrimental to the proper and
timely completion of work. Do not proceed with the work until all unsatisfactory
conditions have been corrected in a manner acceptable to the installer and in accordance
with approved shop drawings.
3.02 INSTALLATION
Comply with specifications and recommendations. Set track and operator plumb, level and
true to line, without warp or rack of doors. Anchor securely in place. Isolate aluminum
and other corrodible materials from sources of electrolytic action at points of contact.
Install complete door operator system in accordance with manufacturer's instructions,
including drive mechanism, controls, and control switches.
3.03 ADJUST AND CLEAN
Adjust operator and controls for optimum condition and safety. Lubricate operating
equipment. Clean surfaces promptly after installation, exercising care to avoid damage of
the protective coating (if any). Advise contractor of protective treatment and other
precautions required through the remainder of the construction period, to ensure that
doors will be without damage or deterioration (other than normal weathering) at the time
of acceptance.
END OF SECTION
|