Elevation
ESA-200 O-SX-SX-O
ESA200E.DXF
(114k)
Other Sections and Details
Head | Sill | Jamb |
Muntin
and Pushbar
Lock Stile | Meeting
Stiles
Problem Downloading DXF File?
Some browsers will open a DXF file as a text document.
If this happens, try right clicking the link above, then select "Save
Target As".
-
Door Construction
Extruded aluminum stile and rail door panels.
Narrow or medium stiles.
Prep'd for ¼" or 1" insulated glass.
204R1 clear or 313R1 dark bronze anodized finishes.
-
Operator
Electromechanical belt drive.
190 lbs per door panel maximum bipart (220) single.
Microprocessor control.
Reverse on contact feature.
Dual infra-red threshold beams.
Motion sensor actuation, both directions
-
Available Options
Enhanced safety and actuation devices.
Automatic electric locking.
Kynar 500 and XL painted finishes.
Stainless steel or bronze muntz metal clad finishes.
Other special finishes are available, consult Eastern Door Service.
|
Center
Biparting Sliding Doors - Four Panels |
|
Unit Size |
Sliding
Door Opening |
| *Breakout
Opening |
| ESA-200 |
ESA-300 |
|
Rough
Opening |
|
8'-0" x 7'-8" |
36" |
|
8'-0½" x
7'-8¼" |
|
9'-0" x 7'-8" |
42" |
|
9'-0½" x 7'-8¼" |
|
10'-0" x 7'-8" |
48" |
|
10'-0½" x
7'-8¼" |
|
12'-0" x 7'-8" |
60" |
|
12'-0½" x 7'-8¼" |
|
14'-0" x 7'-8" |
72" |
|
14'-0½" x 7'-8¼" |
|
16'-0" x 7'-8" |
84" |
|
16'-0½" x
7'-8¼" |
|
Single
Sliding Doors - Two Panels |
|
Unit Size |
Sliding
Door Opening |
| Breakout
Opening |
| ESA-200 |
ESA-300 |
|
Rough
Opening |
|
7'-0" x
7'-8" |
35" |
|
7'-0½" x
7'-8¼" |
|
8'-0" x 7'-8" |
41" |
|
8'-0½" x 7'-8¼" |
|
8'-6" x 7'-8" |
44" |
|
8'-6½" x 7'-8¼" |
|
9'-0" x 7'-8" |
47" |
|
9'-0½" x 7'-8¼" |
*All sliding doors breakout from any
position of the opening or closing cycle. The breakout opening shown
for the ESA-300 is not for emergency egress purposes. Consider that
the sliding doors may be fully closed when they breakout. Use the
breakout opening given for the ESA-200, when considering emergency egress
for the ESA-300.
*UL 325 requires door panels that
breakout for emergency egress not to exceed 41 sq. ft. or 156 Lbs.
|